Любимый тест
Код:
.BOO RK6:
RT-11SJ (S) V05.00
.SET TT NOQUIET
.TYPE V5USER.TXT
RT-11 V5
--------
Installation of RT-11 Version 5 is complete and you are now
executing from the working volume (provided that you have used
the automatic installation procedure). Digital recommends that
you verify the proper operation of your system's software, by
invoking the verification procedure. To do this, enter the
command:
IND VERIFY
Note that VERIFY should be performed only after the dis-
tribution media has been backed up. This was done as part of
automatic installation on RL02 and RX02 based systems, and on
the Micro/PDP-11 (RD51/RX50). If you have not completed auto-
matic installation, you should perform a manual backup before
using VERIFY. Note also that VERIFY is NOT supported on RX01
floppy disks or DECtape I or II.
.DAT
17-Jun-90
.TIM
16:15:57
.SET TT SCOPE
.INI RK:
RK0:/Initialize; Are you sure? Y
.TIM
16:16:56
.$@SYSGEN.BLD
.$@SYSGEN.MON
.ASSIGN RK5 SRC
.ASSIGN RK0 BIN
.ASSIGN RK0 MAP
.ASSIGN RK0 OBJ
.MACRO/OBJ:OBJ:KMSJ SRC:(SJ+SYSGEN.CND+EDTGBL+KMON+KMOVLY)
.MACRO/OBJ:OBJ:RMSJ SRC:(SJ+SYSGEN.CND+EDTGBL+USR+RMONSJ)
.MACRO/OBJ:OBJ:TBSJ SRC:(SJ+SYSGEN.CND+EDTGBL+SYSGEN.TBL)
.MACRO/OBJ:OBJ:BTSJ SRC:(SJ+SYSGEN.CND+EDTGBL+BSTRAP)
.LINK/EXE:BIN:RT11SJ.SYG/BOU:1000/PROMPT/MAP:MAP:RT11SJ OBJ:BTSJ
*OBJ:RMSJ,KMSJ,TBSJ//
Boundary section? OVLY0
.MACRO/OBJ:OBJ:KMFB SRC:(FB+SYSGEN.CND+EDTGBL+KMON+KMOVLY)
.MACRO/OBJ:OBJ:RMFB SRC:(FB+SYSGEN.CND+EDTGBL+USR+RMONFB)
.MACRO/OBJ:OBJ:TBFB SRC:(FB+SYSGEN.CND+EDTGBL+SYSGEN.TBL)
.MACRO/OBJ:OBJ:BTFB SRC:(FB+SYSGEN.CND+EDTGBL+BSTRAP)
.LINK/EXE:BIN:RT11FB.SYG/BOU:1000/PROMPT/MAP:MAP:RT11FB OBJ:BTFB
*OBJ:RMFB,KMFB,TBFB//
Boundary section? OVLY0
.$@SYSGEN.DEV
.ASSIGN RK5 SRC
.ASSIGN RK0 BIN
.ASSIGN RK0 OBJ
.MACRO/OBJ:OBJ:TT SRC:(SYSGEN.CND+TT)
.LINK/EXE:BIN:TT.SYG OBJ:TT
.MACRO/OBJ:OBJ:LD SRC:(SYSGEN.CND+LD)
.LINK/EXE:BIN:LD.SYG OBJ:LD
.MACRO/OBJ:OBJ:VM SRC:(SYSGEN.CND+VM)
.LINK/EXE:BIN:VM.SYG OBJ:VM
.MACRO/OBJ:OBJ:RK SRC:(SYSGEN.CND+RK)
.LINK/EXE:BIN:RK.SYG OBJ:RK
.MACRO/OBJ:OBJ:NL SRC:(SYSGEN.CND+NL)
.LINK/EXE:BIN:NL.SYG OBJ:NL
.TIM
16:18:26
.SHO ALL
RT-11SJ (S) V05.00
Booted from RK6:RT11SJ
USR is set SWAP
EXIT is set SWAP
KMON is set NOIND
TT is set NOQUIET
ERROR is set ERROR
SL is set OFF
EDIT is set EDIT
KMON nesting depth is 3
PDP 11/34 Processor
56KB of memory
FP11 Hardware Floating Point Unit
Extended Instruction Set (EIS)
50 Cycle System Clock
Device I/O time-out support
SJ timer support
Device Status CSR Vector(s)
------ ------ --- ---------
RK Resident 177400 220
TT Installed 000000 000
NL Installed 000000 000
LD Installed 000000 000
VM Not installed 177572 250
SL -Not installed 000000 000
TT
RK (Resident)
RK0 = BIN, MAP, OBJ
RK5 = SRC
RK6 = DK , SY
LD
NL
9 free slots
Job Name Console Level State Low High Impure
--- ---- ------- ----- ----- --- ---- ------
0 RESORC 0 0 Run 000000 145524 N/A
No multi-terminal support
Address Module Words
------- ------ -----
160000 IOPAGE 4096.
157400 RK 128.
145566 RMON 2501.
001000 ..BG.. 25787.
No LD units mounted
.
Время генерации двух мониторов - примерно 1:50 (примерно, потому что две-четыре секунды я набирал $@SYSGEN.BLD
Сейчас повторю тоже на эмуляторе Патрона и отпишусь
- - - Добавлено - - -
На эмулятора Патрона
Код:
.BOO RK5:
RT-11SJ (S) V05.00
.SET TT NOQUIET
.TYPE V5USER.TXT
RT-11 V5
--------
Installation of RT-11 Version 5 is complete and you are now
executing from the working volume (provided that you have used
the automatic installation procedure). Digital recommends that
you verify the proper operation of your system's software, by
invoking the verification procedure. To do this, enter the
command:
IND VERIFY
Note that VERIFY should be performed only after the dis-
tribution media has been backed up. This was done as part of
automatic installation on RL02 and RX02 based systems, and on
the Micro/PDP-11 (RD51/RX50). If you have not completed auto-
matic installation, you should perform a manual backup before
using VERIFY. Note also that VERIFY is NOT supported on RX01
floppy disks or DECtape I or II.
.DAY
Время Дата
17:20:53 17-Июн-1990, Воскресенье
.SHO ALL
RT-11SJ (S) V05.00
Booted from RK5:RT11SJ
USR is set SWAP
EXIT is set SWAP
KMON is set NOIND
TT is set NOQUIET
ERROR is set ERROR
SL is set OFF
EDIT is set EDIT
KMON nesting depth is 3
PDP 11/34 Processor
248KB of memory
Extended Instruction Set (EIS)
KT11 Memory Management Unit
50 Cycle System Clock
Device I/O time-out support
SJ timer support
Device Status CSR Vector(s)
------ ------ --- ---------
RK Resident 177400 220
TT Installed 000000 000
NL Installed 000000 000
LD Installed 000000 000
VM Installed 177572 250
SL -Not installed 000000 000
TT
RK (Resident)
RK5 = DK , SY
LD
VM
NL
8 free slots
Job Name Console Level State Low High Impure
--- ---- ------- ----- ----- --- ---- ------
0 RESORC 0 0 Run 000000 145524 N/A
No multi-terminal support
Address Module Words
------- ------ -----
160000 IOPAGE 4096.
157400 RK 128.
145566 RMON 2501.
001000 ..BG.. 25787.
No LD units mounted
.TIM
17:21:01
.$@SYSGEN.BLD
.$@SYSGEN.MON
.ASSIGN RK5 SRC
.ASSIGN RK0 BIN
.ASSIGN RK0 MAP
.ASSIGN RK0 OBJ
.MACRO/OBJ:OBJ:KMSJ SRC:(SJ+SYSGEN.CND+EDTGBL+KMON+KMOVLY)
.MACRO/OBJ:OBJ:RMSJ SRC:(SJ+SYSGEN.CND+EDTGBL+USR+RMONSJ)
.MACRO/OBJ:OBJ:TBSJ SRC:(SJ+SYSGEN.CND+EDTGBL+SYSGEN.TBL)
.MACRO/OBJ:OBJ:BTSJ SRC:(SJ+SYSGEN.CND+EDTGBL+BSTRAP)
.LINK/EXE:BIN:RT11SJ.SYG/BOU:1000/PROMPT/MAP:MAP:RT11SJ OBJ:BTSJ
*OBJ:RMSJ,KMSJ,TBSJ//
Boundary section? OVLY0
.MACRO/OBJ:OBJ:KMFB SRC:(FB+SYSGEN.CND+EDTGBL+KMON+KMOVLY)
.MACRO/OBJ:OBJ:RMFB SRC:(FB+SYSGEN.CND+EDTGBL+USR+RMONFB)
.MACRO/OBJ:OBJ:TBFB SRC:(FB+SYSGEN.CND+EDTGBL+SYSGEN.TBL)
.MACRO/OBJ:OBJ:BTFB SRC:(FB+SYSGEN.CND+EDTGBL+BSTRAP)
.LINK/EXE:BIN:RT11FB.SYG/BOU:1000/PROMPT/MAP:MAP:RT11FB OBJ:BTFB
*OBJ:RMFB,KMFB,TBFB//
Boundary section? OVLY0
.$@SYSGEN.DEV
.ASSIGN RK5 SRC
.ASSIGN RK0 BIN
.ASSIGN RK0 OBJ
.MACRO/OBJ:OBJ:TT SRC:(SYSGEN.CND+TT)
.LINK/EXE:BIN:TT.SYG OBJ:TT
.MACRO/OBJ:OBJ:LD SRC:(SYSGEN.CND+LD)
.LINK/EXE:BIN:LD.SYG OBJ:LD
.MACRO/OBJ:OBJ:VM SRC:(SYSGEN.CND+VM)
.LINK/EXE:BIN:VM.SYG OBJ:VM
.MACRO/OBJ:OBJ:RK SRC:(SYSGEN.CND+RK)
.LINK/EXE:BIN:RK.SYG OBJ:RK
.MACRO/OBJ:OBJ:NL SRC:(SYSGEN.CND+NL)
.LINK/EXE:BIN:NL.SYG OBJ:NL
.TIM
17:27:42
.
Время генерации - примерно 6:41
Против 1:30 на PDP-2011
Третий вариант - использование HD вместо RK5:
- - - Добавлено - - -
Генерация на эмуляторе Патрона на дисках HD
Код:
.BOO HD5:
HD (177720) disk driver v1.6 2017
RT-11SJ (S) V05.00
.SET TT NOQUIET
.TYPE V5USER.TXT
RT-11 V5
--------
Installation of RT-11 Version 5 is complete and you are now
executing from the working volume (provided that you have used
the automatic installation procedure). Digital recommends that
you verify the proper operation of your system's software, by
invoking the verification procedure. To do this, enter the
command:
IND VERIFY
Note that VERIFY should be performed only after the dis-
tribution media has been backed up. This was done as part of
automatic installation on RL02 and RX02 based systems, and on
the Micro/PDP-11 (RD51/RX50). If you have not completed auto-
matic installation, you should perform a manual backup before
using VERIFY. Note also that VERIFY is NOT supported on RX01
floppy disks or DECtape I or II.
.SET TT SCOPE
.SHO ALL
RT-11SJ (S) V05.00
Booted from HD5:RT11SJ
USR is set SWAP
EXIT is set SWAP
KMON is set NOIND
TT is set NOQUIET
ERROR is set ERROR
SL is set OFF
EDIT is set EDIT
KMON nesting depth is 3
PDP 11/34 Processor
248KB of memory
Extended Instruction Set (EIS)
KT11 Memory Management Unit
50 Cycle System Clock
Device I/O time-out support
SJ timer support
Device Status CSR Vector(s)
------ ------ --- ---------
RK Installed 177400 220
TT Installed 000000 000
NL Installed 000000 000
LD Installed 000000 000
VM Installed 177572 250
SL -Not installed 000000 000
HD Resident 177720 000
TT
HD (Resident)
HD5 = DK , SY
RK
VM
NL
LD
7 free slots
Job Name Console Level State Low High Impure
--- ---- ------- ----- ----- --- ---- ------
0 RESORC 0 0 Run 000000 145644 N/A
No multi-terminal support
Address Module Words
------- ------ -----
160000 IOPAGE 4096.
157520 HD 88.
145706 RMON 2501.
001000 ..BG.. 25827.
No LD units mounted
.TIM
17:48:21
.$@SYSGEN.BLD
.$@SYSGEN.MON
.ASSIGN HD5 SRC
.ASSIGN HD0 BIN
.ASSIGN HD0 MAP
.ASSIGN HD0 OBJ
.MACRO/OBJ:OBJ:KMSJ SRC:(SJ+SYSGEN.CND+EDTGBL+KMON+KMOVLY)
.MACRO/OBJ:OBJ:RMSJ SRC:(SJ+SYSGEN.CND+EDTGBL+USR+RMONSJ)
.MACRO/OBJ:OBJ:TBSJ SRC:(SJ+SYSGEN.CND+EDTGBL+SYSGEN.TBL)
.MACRO/OBJ:OBJ:BTSJ SRC:(SJ+SYSGEN.CND+EDTGBL+BSTRAP)
.LINK/EXE:BIN:RT11SJ.SYG/BOU:1000/PROMPT/MAP:MAP:RT11SJ OBJ:BTSJ
*OBJ:RMSJ,KMSJ,TBSJ//
Boundary section? OVLY0
.MACRO/OBJ:OBJ:KMFB SRC:(FB+SYSGEN.CND+EDTGBL+KMON+KMOVLY)
.MACRO/OBJ:OBJ:RMFB SRC:(FB+SYSGEN.CND+EDTGBL+USR+RMONFB)
.MACRO/OBJ:OBJ:TBFB SRC:(FB+SYSGEN.CND+EDTGBL+SYSGEN.TBL)
.MACRO/OBJ:OBJ:BTFB SRC:(FB+SYSGEN.CND+EDTGBL+BSTRAP)
.LINK/EXE:BIN:RT11FB.SYG/BOU:1000/PROMPT/MAP:MAP:RT11FB OBJ:BTFB
*OBJ:RMFB,KMFB,TBFB//
Boundary section? OVLY0
.$@SYSGEN.DEV
.ASSIGN HD5 SRC
.ASSIGN HD0 BIN
.ASSIGN HD0 OBJ
.MACRO/OBJ:OBJ:TT SRC:(SYSGEN.CND+TT)
.LINK/EXE:BIN:TT.SYG OBJ:TT
.MACRO/OBJ:OBJ:LD SRC:(SYSGEN.CND+LD)
.LINK/EXE:BIN:LD.SYG OBJ:LD
.MACRO/OBJ:OBJ:VM SRC:(SYSGEN.CND+VM)
.LINK/EXE:BIN:VM.SYG OBJ:VM
.MACRO/OBJ:OBJ:RK SRC:(SYSGEN.CND+RK)
.LINK/EXE:BIN:RK.SYG OBJ:RK
.MACRO/OBJ:OBJ:NL SRC:(SYSGEN.CND+NL)
.LINK/EXE:BIN:NL.SYG OBJ:NL
.TIM
17:48:21
17:49:39
.
Время генерации 1:18
Итоговая таблица:
PDP-2011 - 1:30
Эмулятор Патрона с RK - 6:41
Эмулятор Патрона с HD - 1:18
Ну что могу сказать... Скорость регистр-регистр - это ещё не всё
Как и тактовая частота